Clinical Info » Case Studies » KeraSoft3 Case Studies » Patient GF
Male
Age: 27 Years
History: GF had a diagnosis of PMD for around 7 years, the left eye always being worse than the right. He attempted RGP lenses but could not tolerate them and preferred to manage without spectacles at all, as the astigmatism correction in the left eye caused anisometropic symptoms.
| Vision | R: 6/6 pt | L: 6/24 |
| Spectacle Rx | R: Plano/-2.00 x 70 VA 6/6 | L: -2.00/-6.00 x 110 VA 6/9 with strong ghosting |
| Keratometry | R: 7.73 x 68/7.30 x 158 | L: 7.23 x 111/6.37 x 21 |
Topography:
RE LE

Keratoscopy view:
RE LE

Aberrometry:
RE LE

Aberrometry shows that the main HOA is coma for both eyes which is the main reason for the visual symptom of ghosting.
Lens type fitted: KeraSoft®3 by UltraVision produced in Contamac Definitive™ Silicone Hydrogel material
R: 9.00/14.50/-0.50/-2.50 x 66 VA 6/5 L: 8.40/14.50/-0.50/-4.00 x 115 VA 6/6 -2
Keratoscope images of lenses in situ:
RE LE

Topography over lenses:
RE LE

Wearing time: GF achieved 10 -12 hours comfortable wear – effectively all day wear.
He now has binocular vision and good stereopsis which makes a significant difference in driving and playing sports.